Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 10 Cisco ASR 1002-X Router Overview and Installation
Cisco ASR 1002-X Router Power Supplies
Step 4 Using a 3.5mm screwdriver, insert the screwdriver at an angle to release the spring while you install the
stripped lead wire as shown in Figure 10-27.
Figure 10-27 Inserting a Screwdriver Into the +24 VDC Power Supply Terminal Block
Step 5 Carefully push the screwdriver at a forward angle until you relieve the spring contact.
Step 6 With the screwdriver still inserted, gently push the lead wire (ground lead first) in until the copper wire,
as shown in Figure 10-28, is no longer visible (see Figure 10-29).
Caution Ensure that no copper portion of the lead wire is exposed. Only the wire insulation should visible.
Caution Do not install wire into a terminal block that has not had its insulation removed.
Figure 10-28 Cisco ASR 1002-X Router +24 VDC Power Supply Lead Wire Inserted into Terminal
Block
253166
OUTPUT INPUT
FAIL
OK OK
FAN
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
+27V DC INPUT
+27V 32A
1 Lead wire insulation 2 Copper wire
253167
OUTPUT INPUT
FAIL
OK OK
FAN
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
+27V DC INPUT
+27V 32A
1
2

Table of Contents

Other manuals for Cisco ASR 1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1000 Series and is the answer not in the manual?

Cisco ASR 1000 Series Specifications

General IconGeneral
SeriesASR 1000
CategoryNetwork Router
Operating SystemCisco IOS XE
MemoryUp to 64 GB
Interfaces10 Gigabit Ethernet
Power SupplyAC or DC options
DimensionsVaries by model
EncryptionIPsec, SSL
StorageVaries by model
Operating Temperature32°F to 104°F (0°C to 40°C)
Humidity5% to 95% non-condensing
MTBFVaries by model

Related product manuals