9-9
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
78-11380-12
Chapter 9 Configuring IEEE 802.1x Port-Based Authentication
Understanding IEEE 802.1x Port-Based Authentication
If the multiple-hosts mode is enabled on an IEEE 802.1x port, all hosts are placed in the same VLAN
(specified by the RADIUS server) as the first authenticated host.
If IEEE 802.1x and port security are enabled on a port, the port is placed in the RADIUS-server
assigned VLAN.
If IEEE 802.1x is disabled on the port, it is returned to the configured access VLAN.
When the port is in the force authorized, force unauthorized, unauthorized, or shutdown state, it is placed
in the configured access VLAN.
If an IEEE 802.1x port is authenticated and put in the RADIUS-server assigned VLAN, any change to
the port access VLAN configuration does not take effect.
The IEEE 802.1x with VLAN assignment feature is not supported on trunk ports, dynamic ports, or with
dynamic-access port assignment through a VLAN Membership Policy Server (VMPS).
To configure VLAN assignment you need to perform these tasks:
Enable AAA authorization.
Enable IEEE 802.1x (the VLAN assignment feature is automatically enabled when you configure
IEEE 802.1x on an access port).
Assign vendor-specific tunnel attributes in the RADIUS server. The RADIUS server must return
these attributes to the switch:
[64] Tunnel-Type = VLAN
[65] Tunnel-Medium-Type = IEEE 802
[81] Tunnel-Private-Group-ID = VLAN name or VLAN ID
Attribute [64] must contain the value VLAN (type 13). Attribute [65] must contain the value IEEE
802 (type 6). Attribute [81] specifies the VLAN name or VLAN ID assigned to the IEEE
802.1x-authenticated user.
For examples of tunnel attributes, see the “Configuring the Switch to Use Vendor-Specific RADIUS
Attributes” section on page 8-29.
Using IEEE 802.1x with Guest VLAN
You can configure a guest VLAN for each IEEE 802.1x port on the switch to provide limited services
to clients, such as downloading the IEEE 802.1x client. These clients might be upgrading their system
for IEEE 802.1x authentication, and some hosts, such as Windows 98 systems, might not be IEEE
802.1x-capable.
When you enable a guest VLAN on an IEEE 802.1x port, the switch assigns clients to a guest VLAN
when the authentication server does not receive a response to its EAPOL request/identity frame or when
EAPOL packets are not sent by the client.
Before Cisco IOS Release 12.1(22)EA2, the switch did not maintain the EAPOL packet history and
allowed clients that failed authentication access to the guest VLAN, regardless of whether EAPOL
packets had been detected on the interface. You can enable this optional behavior by using the dot1x
guest-vlan supplicant global configuration command.
With Cisco IOS Release 12.1(22)EA2 and later, the switch maintains the EAPOL packet history. If
another EAPOL packet is detected on the interface during the lifetime of the link, network access is
denied. The EAPOL history is reset upon loss of the link.

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz