Page #62 background imageLoading...
Page #62 background image
2-4
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
78-11380-12
Chapter 2 Using the Command-Line Interface
Abbreviating Commands
Abbreviating Commands
You have to enter only enough characters for the switch to recognize the command as unique. This
example shows how to enter the show configuration privileged EXEC command:
Switch# show conf
Using no and default Forms of Commands
Almost every configuration command also has a no form. In general, use the no form to disable a feature
or function or reverse the action of a command. For example, the no shutdown interface configuration
command reverses the shutdown of an interface. Use the command without the keyword no to re-enable
a disabled feature or to enable a feature that is disabled by default.
Configuration commands can also have a default form. The default form of a command returns the
command setting to its default. Most commands are disabled by default, so the default form is the same
as the no form. However, some commands are enabled by default and have variables set to certain default
values. In these cases, the default command enables the command and sets variables to their default
values.
command ? List the associated keywords for a command.
For example:
Switch> show ?
command keyword ? List the associated arguments for a keyword.
For example:
Switch(config)# cdp holdtime ?
<10-255> Length of time (in sec) that receiver must keep this packet
Table 2-2 Help Summary (continued)
Command Purpose

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz