22-4
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
78-11380-12
Chapter 22 Configuring UDLD
Configuring UDLD
Configuring UDLD
This section describes how to configure UDLD on your switch. It contains this configuration
information:
Default UDLD Configuration, page 22-4
Configuration Guidelines, page 22-4
Enabling UDLD Globally, page 22-5
Enabling UDLD on an Interface, page 22-6
Resetting an Interface Shut Down by UDLD, page 22-6
Default UDLD Configuration
Table 22-1 shows the default UDLD configuration.
Configuration Guidelines
These are the UDLD configuration guidelines:
A UDLD-capable interface also cannot detect a unidirectional link if it is connected to a
UDLD-incapable port of another switch.
When configuring the mode (normal or aggressive), make sure that the same mode is configured on
both sides of the link.
Table 22-1 Default UDLD Configuration
Feature Default Setting
UDLD global enable state Globally disabled
UDLD per-interface enable state for fiber-optic media Disabled on all Ethernet fiber-optic interfaces
UDLD per-interface enable state for twisted-pair (copper)
media
Disabled on all Ethernet 10/100 and 1000BASE-TX
interfaces
UDLD aggressive mode Disabled