EasyManua.ls Logo

Cisco IP Phone 6851

Cisco IP Phone 6851
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DescriptionParameter
Enter the rule for calculating daylight saving time; it should include the
start, end, and save values. This rule is comprised of three fields. Each
field is separated by ; (a semicolon) as shown below. Optional values
inside [ ] (the brackets) are assumed to be 0 if they are not specified.
Midnight is represented by 0:0:0 of the given date.
This is the format of the rule: Start = <start-time>; end=<end-time>;
save = <save-time>.
The <start-time> and <end-time> values specify the start and end dates
and times of daylight saving time. Each value is in this format: <month>
/<day> / <weekday>[/HH:[mm[:ss]]]
The <save-time> value is the number of hours, minutes, and/or seconds
to add to the current time during daylight saving time. The <save-time>
value can be preceded by a negative (-) sign if subtraction is desired
instead of addition. The <save-time> value is in this format:
[/[+|-]HH:[mm[:ss]]]
The <month> value equals any value in the range 1-12
(January-December).
The <day> value equals [+|-] any value in the range 1-31.
If <day> is 1, it means the <weekday> on or before the end of the month
(in other words the last occurrence of < weekday> in that month).
Daylight Saving Time Rule
The <weekday> value equals any value in the range 1-7
(Monday-Sunday). It can also equal 0. If the <weekday> value is 0, this
means that the date to start or end daylight saving is exactly the date
given. In that case, the <day> value must not be negative. If the
<weekday> value is not 0 and the <day> value is positive, then daylight
saving starts or ends on the <weekday> value on or after the date given.
If the <weekday> value is not 0 and the <day> value is negative, then
daylight saving starts or ends on the <weekday> value on or before the
date given. Where:
HH stands for hours (0-23).
mm stands for minutes (0-59).
ss stands for seconds (0-59).
Default: 3/-1/7/2;end=10/-1/7/2;save=1.
Daylight Saving Time Rule
(continued)
Enables Daylight Saving Time.
Default: Yes
Daylight Saving Time Enable
Cisco IP Phone 6800 Series Multiplatform Phones Administration Guide