Health monitoring diagnostics are run on in-service expansion modules. The following table describes the
additional tests that are specific to health monitoring diagnostics for expansion modules.
Table 10: Expansion Module Health Monitoring Diagnostics
DescriptionDiagnostic
Monitors port and system status LEDs.LED
Monitors temperature sensor readings.Temperature Sensor
Configuring Online Diagnostics
You can configure the bootup diagnostics to run the complete set of tests, or you can bypass all bootup
diagnostic tests for a faster module boot up time.
We recommend that you set the bootup online diagnostics level to complete. We do not recommend
bypassing the bootup online diagnostics.
Note
Procedure
PurposeCommand or Action
Enters global configuration mode.switch# configure terminal
Step 1
Configures the bootup diagnostic level to trigger
diagnostics when the device boots, as follows:
switch(config)# diagnostic bootup
level [complete | bypass]
Step 2
• complete—Performs all bootup diagnostics. This is
the default value.
• bypass—Does not perform any bootup diagnostics.
(Optional)
Displays the bootup diagnostic level (bypass or complete)
that is currently in place on the switch.
switch# show diagnostic bootup
level
Step 3
The following example shows how to configure the bootup diagnostics level to trigger the complete diagnostics:
switch# configure terminal
switch(config)# diagnostic bootup level complete
Verifying the Online Diagnostics Configuration
Use the following commands to verify online diagnostics configuration information:
   Cisco Nexus 5600 Series NX-OS System Management Configuration Guide, Release 7.x
92 OL-31641-01   
Configuring Online Diagnostics
Configuring Online Diagnostics