Executed CommandsDescriptionAlert Group
show version
show module
show running-config all
show startup-config
Periodic events related to
configuration.
Configuration
show system redundancy status
show tech-support
Events generated by a failure of a
software system that is critical to
unit operation.
System
show environment
show logging last 1000
show module show version
show tech-support platform
callhome
Events related to power, fan, and
environment-sensing elements such
as temperature alarms.
Environmental
show module
show version
show license usage
show inventory
show sprom all
show system uptime
Inventory status that is provided
whenever a unit is cold booted, or
when FRUs are inserted or
removed. This alert is considered
a noncritical event, and the
information is used for status and
entitlement.
Inventory
Smart Call Home maps the syslog severity level to the corresponding Smart Call Home severity level for
syslog port group messages.
You can customize predefined alert groups to execute additional show commands when specific events occur
and send that show output with the Smart Call Home message.
You can add show commands only to full text and XML destination profiles. Short text destination profiles
do not support additional show commands because they only allow 128 bytes of text.
Smart Call Home Message Levels
Smart Call Home allows you to filter messages based on their level of urgency. You can associate each
destination profile (predefined and user defined) with a Smart Call Home message level threshold. The switch
does not generate any Smart Call Home messages with a value lower than this threshold for the destination
profile. The Smart Call Home message level ranges from 0 (lowest level of urgency) to 9 (highest level of
urgency), and the default is 0 (the switch sends all messages).
Smart Call Home messages that are sent for syslog alert groups have the syslog severity level mapped to the
Smart Call Home message level.
Cisco Nexus 5600 Series NX-OS System Management Configuration Guide, Release 7.x
118 OL-31641-01
Configuring Smart Call Home
Smart Call Home Message Levels