PurposeCommand
Displays abbreviated interface information.show interface brief
Displays snapshots present on the switch.
show snapshots before-maintenance-mode
description
Displays the details of the config-profile files.
show config-profile name
show system mode Command
switch# show system mode
System Mode : Maintenance
show interface brief Command
switch# show interface brief
-----------------------------------------------------------------------------
Ehternet VLAN Type Mode Status Reason Speed Port
Interface Ch #
-----------------------------------------------------------------------------
Eth1/1 - - eth routed down sysIntfShut 10G(D) - -
Eth1/2 - - eth routed down sysIntfShut 10G(D) - -
Eth1/3 - - eth routed down sysIntfShut 10G(D) - -
Eth1/4 - - eth routed down sysIntfShut 10G(D) - -
Eth1/5 - - eth routed down sysIntfShut 10G(D) - -
Eth1/6 - - eth routed down sysIntfShut 10G(D) - -
Eth1/7 - - eth routed down SFP not inserted 10G(D) - -
Eth1/8 - - eth routed down SFP not inserted 10G(D) - -
Eth1/9 - - eth routed down SFP not inserted 10G(D) - -
Eth1/10 - - eth routed down SFP not inserted 10G(D) - -
Eth1/12 - - eth routed down SFP not inserted 10G(D) - -
Eth1/13 - - eth routed down SFP not inserted 10G(D) - -
Eth1/14 - - eth routed down SFP not inserted 10G(D) - -
Eth1/15 - - eth routed down SFP not inserted 10G(D) - -
Eth1/16 - - eth routed down SFP not inserted 10G(D) - -
-------------------------------------------------------------------------------
Port-channel VLAN Type Mode Status Reason Speed Protocol
Interface
-------------------------------------------------------------------------------
Po1 1 eth access down No operational members auto(I) none
Po100 1 eth access down No operational members auto(I) none
-------------------------------------------------------------------------------
Port VRF Status IP Address Speed MTU
-------------------------------------------------------------------------------
mgmt0 - - up 192.0.0.1 1000 1500
switch#
show snapshots Command
switch# show snapshots
Snapshot Name
---------------------------------------------------------------------------------------
snapshot_before_maintenance Wed Sep 10 20:19:31 2014 system-internal-snapshot
snapshot_after_maintenance Wed Sep 10 20:29:54 2014 system-internal-snapshot
snap1 Wed Sep 10 20:36:15 2014 For testing
Cisco Nexus 5600 Series NX-OS System Management Configuration Guide, Release 7.x
320 OL-31641-01
Configuring GIR (Cisco NX-OS Release 7.1(0)N1(1))
Verifying GIR

Table of Contents

Other manuals for Cisco Nexus 5600 Series

Related product manuals