Form No. 56043161 - Clean Track
®
L24 - 61
Caution!
Acidcanspillontotheoorifthebatteriesareoverlled.
3. Tighten the vent caps.
4. Wash the tops of the batteries with a solution of baking soda and water (2 tablespoons of baking soda to 1 liter of
water).
Charging Gel (VRLA) Batteries
Chargethebatterieseachtimethemachineisused,orwhentheBatteryIndicator(D2) is reading less than full.
Warning!
• Charge batteries in a well-ventilated area.
• Do not smoke while servicing the batteries.
When Servicing Gel (VRLA) Batteries
• Removealljewelry.
• Do not smoke.
• Wearsafetyglasses,rubberglovesandarubberapron.
• Work in a well-ventilated area.
• Do not allow tools to touch more than one battery terminal at a time.
• ALWAYSdisconnectthenegative(ground)cablerstwhenreplacingbatteriestopreventsparks.
• ALWAYS connect the negative cable last when installing batteries.
Caution!
Your voltage regulated lead acid (VRLA) battery will deliver superior performance and life only if it recharged
correctly! Under or overcharging will shorten battery life and limit performance. Be sure to follow correct charging
instructions! Do not attempt to open this battery! IfaVRLAbatteryisopened,itlosesitspressureandtheplates
become oxygen contaminated. The warranty will be voided if the battery is opened.
If your machine shipped with an onboard battery charger, do the following:
1. Turn the Key Switch (A) off.
2. Unwind the electrical cord from the side of the onboard charger and plug it into a properly grounded outlet. Refer to
the OEM product manual for more detailed operating instructions.