24 - Form No. 56043161 - Clean Track
®
L24
Solution System Maintenance
Solution Tank
1. Empty the solution tank weekly.
2. Remove the solution Drain Hose from its storage area (located on the right rear control handle compartment).
Direct the hose to a designated “Disposal Site” and ush the tank with clean water.
Solution Filter
See Figure 4. Remove and clean the in-line Solution Filter (C). To access the lter housing for removal, work
underneath the middle left side chassis panel. No tools are needed to remove the lter (hand-tighten only).
Service Tip: The solution shutoff valve (B) must be placed in the OFF (Closed) position. This prevents loss
of solution when servicing the filter strainer with a partial or full tank.
Troubleshooting Guide
Problem Possible Cause
Inadequate Solution Flow
No solution in the tank
Solution tank lter ball valve in the off position
Clogged solution lter, valves and/or hoses
*Reference the Solution System Troubleshooting Guide owchart in this manual section for further component
diagnostics.
Solution System - Electrical Troubleshooting Guide
Possible Symptoms
1. No solution ow while in the scrub auto solution mode.
2. Solution Pump will not operate:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clarke Clean Track® L24 56317170 and is the answer not in the manual?

Clarke Clean Track® L24 56317170 Specifications

General IconGeneral
BrandClarke
ModelClean Track® L24 56317170
CategoryFloor Machine
LanguageEnglish

Related product manuals