Error
Codes Error Description Recommended Action
------------------------------------------------------------------------------
2417 - 01 Lightpen text mode failed - no The following steps apply
response to error codes 2417 - 01
through 2417 - 04:
2417 - 02 Lightpen text mode test failed -
invalid response 1. Replace the lightpen
and retest.
2417 - 03 Lightpen medium resolution mode test 2. Replace the COMPAQ
failed - no response Enhanced Color Graphics
Board ROM and retest.
2417 - 04 Lightpen medium resolution mode test 3. Replace the COMPAQ
failed - invalid response Enhanced Color Graphics
Board and retest.
4. Replace the system
board and retest.
------------------------------------------------------------------------------
2418 - 01 ECG memory test failed The following steps apply
to error codes 2418 - 01
2418 - 02 ECG shadow RAM test failed through 2425 - 01:
2419 - 01 ECG ROM checksum test failed 1. Verify switch settings.
2. Replace the COMPAQ
2420 - 01 ECG attribute test failed Enhanced Color Graphics
Board ROM.
2421 - 01 ECG 640 x 200 graphics mode test 3. Replace the COMPAQ
failed Enhanced Color Graphics
Board and retest.
2422 - 01 ECG 640 x 350 16 Color Set test 4. Replace the system
failed board and retest.
2423 - 01 ECG 640 x 350 64 Color Set test failed
2424 - 01 ECG Monochrome Text Mode test failed
2425 - 01 ECG Monochrome Graphics Mode test
failed
==============================================================================
Table 5-12. Pointing Device Interface Test Error Codes
==============================================================================
Error
Codes Error Description Recommended Action
------------------------------------------------------------------------------
8601 - xx Pointing device test l. Verify switch settings
on Multipurpose
8601 - 02 Left button is inoperative Controller Board,
Multipurpose Fixed Disk
8601 - 03 Left button is stuck closed Drive Controller Board,
or Serial/Parallel
8601 - 04 Right button is inoperative Interface Board.
2. Replace the pointing
8601 - 05 Right button is stuck closed device with a working
pointing device and
8601 - 06 Left block not selected retest.