UT-4500 Series C- and Ku-Band Up Converters MN/UT4500.IOM
Front Panel Operation Revision 3
6–18
Converter Temp = +30.0C
IFLO Tuning = 0.38V
Synth Tuning: Sum=0.32V
Coarse=06.0V Fine=03.5V
Press ENTER or CLEAR to continue.
6.2.5 (SELECT:) FAULTS Menu Branch
The MASK selection is disabled in redundancy systems.
CURRENT STORED MASK
Use the keys to select CURRENT, STORED, or MASK. Press ENTER.
6.2.5.1 (FAULTS:) CURRENT
Four read-only information screens are provided to monitor a number of
operating parameters and return back whether the parameters are OK
(operating within normal ranges), or FT (currently faulted). These examples are
provided for reference only the data varies depending on the operating
conditions for the system in use:
Power Faults: 15VDC=OK
14VDC=OK VCC=OK
IFLO Lock Detect = OK
Synth Faults: SumLD=OK
FineLD=OK CoarseLD=OK