UT-4500 Series C- and Ku-Band Up Converters MN/UT4500.IOM
Serial Interface Operation Revision 3
8–26
>DEV/SAM_xx_y{cr}{lf}] where:
xx = converter number 01 to 12
y = A for Auto; M for Manual
8.7.4.4 FBU (Force Backup)
Use FBU to force a backup condition for maintenance and test purposes. This
command is only accepted by the backup converter (i.e., “BU”). When activated,
this command forces the chain converter offline, and forces the backup
converter to assume the state of the specified chain converter.
>DEV/FBU_xx_y{cr}{lf}] where:
xx = converter number 01 to 12
y = ‘F’ to force a backup, ‘N’ to remove a backup
>DEV/FBU_xx_zzzzz{cr}{lf}] where:
xx = converter number 01 to 12
zzzzz = ‘NONE’ if no backup active (converter number is not displayed);
‘ACTIVE’ if an automatic backup has occurred;
‘FORCED’ if a forced backup is active