Chapter 5 Running Mode And Controlling Wiring
42
5.2.3 Parameter Settings In Speed Mode
Parameter
Introduction
Range
Default Value
FA4
Control Mode
1
0
FA5
Speed Proportional Gain
5-2000Hz
150
FA6
Speed Integral Constant
1-1000ms
75
FA22
Internal And External Speed
Instruction Selection
0-5
0
FA24
Internal Speed 1
-6000-6000r/min
100
FA25
Internal Speed 2
-6000-6000r/min
500
FA26
Internal Speed 3
-6000-6000r/min
1000
FA27
Internal Speed4
-6000-6000r/min
2000
FA28
Arrival Speed
0-3000r/min
3000
FA40
Acceleration Time Constant
1-10000ms
100
FA41
Deceleration Time Constant
1-10000ms
100
FA42
S Type Acceleration And
Deceleration Time Constant
0-1000ms
0
FA43
Gain Of Analog Speed Command
10-3000r/min/v
300
FA44
Direction Of Analog Speed
Command
0-1
0
FA45
Zero Offset Compensation Of
Analog Speed Command
-5000-5000
0
FA46
Filter Of Analog Speed Command
1-300Hz
300
FA75
Zero-speed Detection Point
0-1000r/min
10
FA76
The Setting Value For Speed
Consistent
0-1000r/min
10
FA87
Hysteresis Of Arrival Speed
0-5000r/min
30
FA88
Polarity Of Arrival Speed
0-1
0

Table of Contents