Chapter 5 Running Mode And Controlling Wiring
49
5.5 Pre-operational Inspection
Before connecting the load, the motor should be run for checking.
Check and ensure before running:
1There is no obvious damage to the appearance of the servo drive.
2Wiring terminals are insulated.
3There are no conductive objects, such as screws or metal plates, combustible objects inside
the drive, and no conductive objects at the connection port.
4Do not place the servo drive or a external brake resistor on combustibles.
5Please wire correctly.
Driver power supply, auxiliary power supply, grounding end and other wiring should be
wired correctly. Each control signal cable connection should be correct. Each limit switch,
protection signal have been correctly connected.
1Enabled switch in OFF state.
2Cut off power supply circuit and stop alarm circuit to maintain access ope.
3 Servo driver applied voltage reference should be correct.
Power the servo drive when the controller does not send a running command signal. Check
and guarantee:
1 The servo motor can turn normally without vibration or operating sound phenomenon.
2 All parameters are set correctly, according to different mechanical characteristics and please
do not over-set extreme parameters.
3 Bus voltage indicator lamp and digital tube display are normal.