Section
Item
Maintenance item contents
Initial
No. setting*
2AV/X
1-4-54
1-4
High voltage
Developing
Fixing and
cleaning
Operation
panel and
support
equipment
Mode setting
U100 Setting the surface potential 184
U101 Setting high voltages
• Developing bias 193/38
• Transfer voltage 115
• Transfer voltage output timing –176
U109 Setting the drum type H
U110 Checking/clearing the drum count —
U111 Checking/clearing the drum drive time —
U130 Initial setting for the developer —
U131 Setting the toner sensor control voltage 155
U132 Replenishing toner forcibly —
U135 Checking toner feed motor operation —
U155 Displaying the toner sensor output —
U156 Changing the toner control level
• Toner feed start level 100
• Toner empty level 44
U157 Checking/clearing the developing drive time —
U158 Checking/clearing the developing count —
U161 Setting the fixing control temperature
• Primary stabilization fixing temperature 135
• Secondary stabilization fixing temperature 160
• Regular stabilization control temperature 180
• Temperature to be deducted from the regular control temperature 0
when copying onto small-sized paper
U162 Stabilizing fixing forcibly —
U163 Resetting the fixing problem data —
U196 Turning the fixing heater on —
U199 Checking the fixing temperature —
U200 Turning all LEDs on —
U203 Operating DF separately —
U204 Setting the presence or absence of a key card or key counter —
U207 Checking the operation panel keys —
U243 Checking the operation of the DF motors —
U244 Checking the DF switches —
U250 Setting the maintenance cycle 100
U251 Checking/clearing the maintenance count —
U252 Setting the destination Japan
U253 Switching between double and single counts Double count
U254 Turning auto start function on/off On
U255 Setting auto clear time 120
U256 Turning auto preheat/energy saver function on/off On
U258 Switching copy operation at toner empty detection Single mode,
70
U260 Changing the copy count timing After ejection
U265 Setting the destination specifications 0
U332 Setting the size conversion factor —
U342 Setting the ejection restriction On
U344 Setting preheat/energy saver mode Energy star
U345 Setting the value for maintenance due indication 0
U348 Setting the copy density adjustment range Normal
* Initial setting for executing maintenance item U020