3A7
1-4-5
(4) Adjusting the DF magnification
Adjust magnification in the auxiliary scanning direction if magnification is incorrect when the DF is used.
U053
U403
U402 U066
U070
U071
(P. 1-4-9)
U404
(P. 1-4-13)
U065
U034
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
• 20 cpm copier
Enter maintenance mode.
Place an original on the DF
and make a test copy.
Yes
No
Start
End
Exit maintenance mode.
Press the stop/clear key.
Is the image correct?
Enter “070” using
the numeric keys.
Press the interrupt key.
Setting range: –25 to +25
Changing the value by 1 changes
the magnification by 0.1%.
Reference: 0
Change the setting using the
cursor left/right keys.
• For copy example 1, increase
the value to make the copy
image longer.
• For copy example 2, decrease
the value to make the copy
image shorter.
Press the start key.
Press the start key.
The new setting is stored.
Auxiliary
scanning
direction
Original
Main scanning
direction
Copy
example 1
Copy
example 2
Figure 1-4-8