The procedure for moistening the sponge is described in the chapter on ordinary maintenance of
the humidifier cap, specifically in chapter 8.4.
5.7 Calibration
Since the characteristics of the colorant in relation to the circuit containing it greatly affect the
machine's precision, it is essential to CALIBRATE all of the dispensing circuits. The CorobTECH
program allows you to automatically calibrate the machine starting from theoretical calibration
parameters.
We recommend that you use CorobTECH, last released version.
After filling the canisters, we recommend leaving the colorant to degas from air for 8-12
hours before calibrating; during this time it is advisable to increase the automatic stirring
frequency so that the colorants are in ideal condition during calibration.
To calibrate the machine, you must use a precision scale since the actual calibration parameters
are calculated based on the weight of the amounts dispensed during calibration.
You may use an electronic scale that can interface with the computer, among those managed by
the calibration program. See the scale manual for instructions on interfacing the scale with the
machine management computer. In any case, it is advisable to use the COM2 serial port on the
computer.
The actual specific weights of the colorants present in the machine must be entered into the
calibration program.
The instructions for automatically calibrating the dispensing circuits of the machine are described
in detail in the program user's manual.