7-USING THE DISPENSER 7-7
COROB™ TATOCOLOR
Never exceed the maximum colorant level in the canister, approximately 1.5 cm under the
recirculation connector (Figure 7-5).
Never pour colorant directly onto the stirrer shaft (Figure 7-4/Figure 7-5).
Figure 7-4
Figure 7-5
5. Close the canister with its corresponding lid.
6. Repeat the above steps to fill other canisters.
7. Close the canister section covers and restart the machine by releasing the ON-OFF button.
Each time colorant is added to the canisters, it is essential to update the amount of
colorant associated with the topped up canisters, entering the new colorant level in the program
(see the application program user's manual).
Update the levels IMMEDIATELY AFTER topping up the colorant in the machine canisters,
so that you do not forget to do so later.
Changing the levels so that they do not match the actual amount of colorant added to the
canisters may compromise the accuracy of the hue produced or, worse yet, cause
malfunctions in the machine due to emptying the canisters and circuits.
After topping up, it is advisable to carry out the recirculation and stirring processes using the
functions provided in the management application program, to eliminate any air that may be
emulsified and incorporated into the colorant.