8-4 8-ORDINARY MAINTENANCE
COROB™ TATOCOLOR
The type of cleaning product to use depends on the type of colorants used on the machine; follow
the table given in chapter 8.1 for the type of solution to be used.
Should mould form in the autocap and in the sponges it is advisable to use the following
fluids:
Propylene glycol solution, 50% by volume, in water;
AgCl solution in water;
Bleach.
Visually check the status of the sponge and moisten as needed. The level of the humidifying liquid
must not exceed the height of the sponge.
If it is very dirty, remove the sponge from the cap and wash it thoroughly.
Replace it if it is severely damaged.
Do not use sponges different from the ones supplied.
Follow the instructions in the table below to correctly intervene based on the accessories installed
on the machine.
Model/Accessories Cleaning the nozzles
TATOCOLOR TB
with sliding cap
– Shut off the machine and unplug the power supply
cable (chapter 6.4).
– Open the sliding cap by pushing the opening bar inward with
your hand.
– Unscrew the sponge holding lid and remove it.
– Release the lever of the sliding cap to bring it back in its
closed position.
– Wash the holding lid and perform maintenance on the sponge.
– Push the opening bar to cause the cap to open.
– Screw back the sponge holding lid.
– Release the lever of the sliding cap to bring it back in its
closed position.
– Connect the machine to the power mains and switch it on
(chapter 6.2).
TATOCOLOR TB
with sliding autocap
– Open the autocap by loading a can on the machine.
– Shut off the machine and unplug the power supply
cable (chapter 6.4).
– Unscrew the sponge holding lid and remove it.
– Wash the holding lid and perform maintenance on the sponge.
– Screw back the sponge holding lid.
– Connect the machine to the power mains and switch it on
(chapter 6.2); the autocap closes automatically when the can
is removed from the shelf.
RISK OF CRUSHING
TATOCOLOR TA