4 — MONITOR MENU
pg. 57
Return to TOC Curtis Model 1226 – September 2019
MONITOR MENU — CONTROLLER MENU, cont’d
FIELD VALUES DESCRIPTION
Charge Inhibit On/Off Indicates whether the charge inhibit function is active.
Lift Lockout On/Off Indicates whether the hydraulic lift lockout function is active.
The Lift Lockout Threshold parameter species the battery level at which
the controller activates hydraulic lift lockout. See page 42.
Emer Rev On/Off Indicates whether the emergency reverse function is active.
Hydraulic Input On/Off Indicates whether the hydraulic function is active.
Load Hold Input On/Off Indicates whether the load hold function is active.
Push Status 0-255 Indicates the status of the push function.
Mismatch Error 0-255 Indicates the mismatch type if a Parameter Mismatch fault is active. The
following list describes the parameter values:
1 = The throttle deadband is miscongured. For example, this fault would
occur if the value of the Forward Deadband parameter is greater than
the value of the Forward Max parameter.
3 = The Aux 1 or Aux 2 output is congured as the belly button check
output, but Driver 2 is not set as a high side driver.
4 = The speed mode’s Max Speed parameter is less than its Min Speed
parameter.
5 = The EMR Input Type species complementary switches but the NO or
NC switch is not assigned.
6 = The Aux 1 and Aux 2 drivers are being used by the same function.
Values other than those listed above are reserved for future use.
Supervision Error 0-65535 If a Supervision fault is active, this eld provides diagnostic information on
the fault’s cause. See Table 29.
Table 29 Supervision Error Field Values
Value Description
200 The primary and supervisory microprocessors’ keyswitch input voltages do not match.
301 The primary and supervisory microprocessors’ Switch 1 statuses do not match.
302 The primary and supervisory microprocessors’ Switch 2 statuses do not match.
303 The primary and supervisory microprocessors’ Switch 3 statuses do not match.
304 The primary and supervisory microprocessors’ Switch 4 statuses do not match.
305 The primary and supervisory microprocessors’ Switch 5 statuses do not match.
306 The primary and supervisory microprocessors’ Switch 6 statuses do not match.
307 The primary and supervisory microprocessors’ Switch 7 statuses do not match.
308 The primary and supervisory microprocessors’ Switch 8 statuses do not match.
309 The primary and supervisory microprocessors’ Switch 9 statuses do not match.
310 The primary and supervisory microprocessors’ Switch 10 statuses do not match.
311 The primary and supervisory microprocessors’ Switch 11 statuses do not match.
312 The primary and supervisory microprocessors’ Switch 12 statuses do not match.
313 The primary and supervisory microprocessors’ Switch 13 statuses do not match.