3 — PROGRAMMABLE PARAMETERS
Curtis Model 1226 – September 2019
Return to TOC
pg. 42
BATTERY MENU — BDI SETUP MENU, cont’d
PARAMETER VALUES DEFAULT DESCRIPTION
BDI Reset Percent 0%-100% 75% Sets the percentage of battery voltage above which the BDI
percentage will not reset when the keyswitch is turned on.
When a battery has a high BDI percentage, its oat voltage when
the keyswitch is powered on could cause false BDI resets. The
BDI Reset Percent parameter lets you preempt this problem by
specifying a minimum threshold for resetting the BDI percentage.
Full Charge Voltage 0.90-3.00V 2.35V Sets the voltage above which the controller considers the battery
as nished charging.
Start Charge Voltage 0.90-3.00V 2.10V Sets the voltage at which the controller considers the battery as
starting to charge.
Charge Time 0-600 minutes 300 Species how many minutes it takes for the BDI percentage to
increase from 0% to 100% while the battery is being charged.
When a charger is plugged in, the battery voltage gradually
increases to the full level.
To accurately reect the state-of-charge, during charging the
BDI percentage increases by 1% when the specied number of
minutes elapses.
Note: Higher battery amp/hour ratings require a larger Charge
Time.
Lift Lockout Threshold 0-%50% 20% Sets the BDI percentage at or below which the controller
activates the hydraulic lift lockout function.
Note: When hydraulic lift lockout is active, the controller disables
the hydraulic lift to prevent battery damage.
Emergency Reverse Menu
You can congure many aspects of the emergency reverse feature, including the following:
Whether emergency reverse is activated by a normally open switch, normally
closed switch, or both normally open and normally closed switches.
Whether the operator can activate emergency reverse while driving in reverse.
How long the vehicle will operate while an emergency reverse switch is active.
e rate at which the vehicle decelerates to a stop.
e rate at which the vehicle accelerates in the reverse direction.
How the controller handles belly button wiring (BB Wiring) faults.
Use the parameters in the following table to congure the emergency reverse feature.