5 — INITIAL SETUP
pg. 65
Return to TOC Curtis Model 1226 – September 2019
Note: You’ll monitor the Motor Resistance Measured field in the following steps.
8. With the speed limit pot set at maximum, apply the throttle full forward, driving the vehicle
against the immovable object.
9. Note the Motor Resistance Measured fields value.
10. Repeat steps 8 and 9 three more times
11. Select Program » Motor Setup » Motor.
12. Set the System Resistance parameter to the average of the 4 Motor Resistance Measured values.
13. Before tuning the vehicle as described on page 66, reset the following parameters to their
original values:
Auto Comp Current Limit
Boost Enable