DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Web UI Reference Guide
458
Log Description Severity
Log Message: Unit <unitID> External Alarm Channel < channelID> :< alarmMsg >
Parameters description:
unitID: The unit ID.
channelID: The channel ID.
alarmMsg: The alarm Msg.
Event description: Chip temperature over 107 C.
Log Message: Chip temperature over 107 C.
Warning
Event description: Chip temperature over 110 C.
Log Message: Chip temperature over 110 C.
Critical
Event description: Chip temperature back to 107 C below.
Log Message: Chip temperature back to 107 C below.
Notice
Port
Log Description Severity
Event description: port linkup
Log Message: Port <port> link up, <nway>
Parameters description:
port: Represents the logical port number.
nway: Represents the speed and duplex of link.
Informational
Event description: port link down
Log Message: Port <port> link down
Parameters description:
port: Represents the logical port number.
Informational
Port Security
Log Description Severity
Event description: Address full on a port
Log Message: MAC address <mac-address> causes port security violation on <interface-
id>.
Parameters description:
macaddr: The violation MAC address.
interface-id: The interface name.
Warning
Event description: Address full on system
Log Message: Limit on system entry number has been exceeded.
Warning
Safeguard
Log Description Severity
Event description: When the CPU utilization is over the rising threshold, the Switch enters
exhausted mode, and the syslog will be recorded.
Log Message: Unit <unit-id>, Safeguard Engine enters EXHAUSTED mode.
Parameters description:
unit-id: Unit ID.
Warning
Event description: When the CPU utilization is lower than the falling threshold, the Switch Informational