Local Configurations 290
Figure 5-263
Configure the settings for the system maintenance parameters. See Table 5-79. Step 2
Parameter
Description
Auto Reboot
In the Auto Reboot list, select the reboot time.
Case Fan Mode
In the Case Fan Mode list, you can select Always run or Auto. If
you select Auto, the case fan will stop or start according to the
external conditions such as the Device temperature.
Not all models support this function, and it is only supported on
the local configuration interface.
Table 5-79
Click Apply to complete the settings. Step 3
5.19.5 Exporting and Importing System Settings
You can export or import the Device system settings if there are several Devices that require
the same setup.
The IMP/EXP interface cannot be opened if the backup operation is ongoing on the other
interfaces.
When you open the IMP/EXP interface, the system refreshes the devices and sets the
current directory as the first root directory.
Click Format to format the USB storage device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua DH-XVR1B08 and is the answer not in the manual?

Dahua DH-XVR1B08 Specifications

General IconGeneral
Audio Input1 channel, RCA
Audio Output1 channel, RCA
Video Output1 HDMI, 1 VGA
USB2 USB 2.0 ports
Power SupplyDC12V/1.5A
Video CompressionH.265/H.264
Analog Camera Input8 channels, BNC
IP Camera Input8
HDD1 SATA port, up to 6TB
Network1 RJ-45 port (10/100 Mbps)
Operating Temperature-10°C to +55°C
Operating Humidity10% to 90%
Max Recording Resolution1080N/720p/960H/D1/CIF