Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual 29
Teledyne DALSA 03-032-20117-01
At this point you are ready to start operating the camera in order to acquire images, set camera functions,
and save settings.
Camera Operation
Factory Settings
When the camera is powered up for the first time, it operates using the following factory settings:
High sensitivity mode
Forward CCD shift direction
No binning
Exposure mode 7 (Programmable line rate & max exposure time)
5000 Hz line rate
Readout mode: Off
Mirroring mode: 0, left to right
Factory calibrated analog gain and offset
8 bit output
sag enabled (1k and 2k use). (It is recommended that you use the ssg command with the 4k in
order to maintain valid LUT calibration.)
LUTs enabled (4k default), factory calibrated @ -10 dB.
Returning Camera Settings
The camera parameter screen (obtained using the gcp command) returns all of the camera’s current
settings. The table below lists all of the gcp screen settings.