Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual 43
Teledyne DALSA 03-032-20117-01
Setting the Exposure Time
Sets the cam eras exposure time is µs. Camera mu st be operating in m od e 2, 6, or 8.
Camera Link Command
Parameter
Description
Notes
set f
Desired exposure time in µs.
Allowable range is 3 to 3300µs.*
To read the current line frequency, use the
command gcp or get set.
If you enter an invalid line rate frequency, an
error message is returned.
*The exposure time range is based on the
current line rate.
To determine the maximum exposure time
allowed for the current line rate, use the
command get ger.
Example
set 400.5
Baud Rate
Determines the speed of the serial communication port in bps.
Camera Link Command
Parameter
Description
Notes
sbr m
Baud rate. Available baud rates are:
9600 (Default), 19200, 57600, and
115200.
Power-on rate is always 9600 baud.
The rc (reset camera) command will not reset the
camera to the power-on baud rate and will
reboot using the last used baud rate.
Example
sbr 57600

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa Spyder3 S3-14-01k40-00-R and is the answer not in the manual?

Dalsa Spyder3 S3-14-01k40-00-R Specifications

General IconGeneral
BrandDalsa
ModelSpyder3 S3-14-01k40-00-R
CategorySecurity Camera
LanguageEnglish

Related product manuals