Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual 59
Teledyne DALSA 03-032-20117-01
Returning Calibration Results and Errors
Returning All Pixel Coefficients
Returns all the cu rrent pixel coefficients in the order FPN , PRNU, FPN , PRNU… for the range specified
by x1 and x2. The camera also returns the pixel number with every fifth coefficient.
Camera Link Command
x1: Start pixel to display in a range
from 1 to sensor pixel count.
x2 End pixel to display in a range from
x1 to sensor pixel count.
This function returns all the current pixel
coefficients in the order FPN, PRNU, FPN,
PRNU… The camera also retu rns the p ixel
number with each coefficient.
Returning FPN Coefficients
Returns a pixel’s FPN coefficient value in DN (12 bit LSB)
Camera Link Command
The pixel number to read in a range
from 1 to sensor pixel count.
Returning PRNU Coefficients
Returns a pixel’s PRN U coefficient value in DN (12 bit LSB)
Camera Link Command
i The pixel number to read in a range
from 1 to sensor pixel count.