13-16 RS-FF Operand R
Array [8]
Select the reset input. The reset input takes priority over the set
input.
Option: Function:
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[37] Digital input DI32
[38] Digital input DI33
[39] Start command
[40] Drive stopped
[41] Reset Trip
[42] Auto Reset Trip
[43] OK Key
[44] Reset Key
[45] Left Key
[46] Right Key
[47] Up Key
[48] Down Key
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[75] Start command given
[76] Digital input x30/2
[77] Digital input x30/3
[78] Digital input x30/4
[80] No Flow
[81] Dry Pump
[82] End of Curve
[83] Broken Belt
[90] ECB Drive Mode
[91] ECB Bypass Mode
[92] ECB Test Mode
[93] Emergency Mode
[94] RS Flipop 0
[95] RS Flipop 1
[96] RS Flipop 2
[97] RS Flipop 3
13-16 RS-FF Operand R
Array [8]
Select the reset input. The reset input takes priority over the set
input.
Option: Function:
[98] RS Flipop 4
[99] RS Flipop 5
[100] RS Flipop 6
[101] RS Flipop 7
[102] Verifying Flow
[103] Relay 1
[104] Relay 2
[105] Relay 3
[106] Relay 4
[107] Relay 5
[108] Relay 6
[109] Relay 7
[110] Relay 8
[111] Relay 9
[112] System On Ref
[125] Digital input x46/1
[126] Digital input x46/3
[127] Digital input x46/5
[128] Digital input x46/7
[129] Digital input x46/9
[130] Digital input x46/11
[131] Digital input x46/13
[140] ATEX ETR cur. warning
[141] ATEX ETR cur. alarm
[142] ATEX ETR freq. warning
[143] ATEX ETR freq. alarm
3.12.4 13-2* Timers
Use the result (true or false) from timers directly to dene
an event (see parameter 13-51 SL Controller Event), or as
boolean input in a logic rule (see parameter 13-40 Logic
Rule Boolean 1, parameter 13-42 Logic Rule Boolean 2, or
parameter 13-44 Logic Rule Boolean 3). A timer is only false
when started by an action (for example [29] Start timer 1)
until the timer value entered in this parameter has elapsed.
Then it becomes true again.
All parameters in this parameter group are array
parameters with index 0–2. Select index 0 to program
timer 0, select index 1 to program timer 1, and so on.
Parameter Description Programming Guide
MG20OB02 Danfoss A/S © 05/2018 All rights reserved. 121
3 3

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AQUA Drive FC 202 and is the answer not in the manual?

Danfoss VLT AQUA Drive FC 202 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AQUA Drive FC 202
CategoryDC Drives
LanguageEnglish

Related product manuals