____________________________________________________________________________________________________________ MODELMODEL 25002500
STAND-ALONE DOWNLOAD PROGRAM EXAMPLES
Following are several examples of the command line for the downloading of
LOAD2500 configurations:
- LOAD2500 1 D533011B B1200 ID12
This example illustrates the downloading of application number
D533011B through communications port 1, at a 1200 baud rate, and
sets the Comm ID to 12.
- LOAD2500 2 D533011B ID24
This example illustrates the downloading of application number
D533011B through communications port 2, at the default baud rate of
2400, and sets the Comm ID to 24.
- LOAD2500 1 C511009A B300
This example illustrates the downloading of application number
C511009A through communications port 1, at a 300 baud rate, and
sets the Comm ID to the default value of 1.
_________________________________________________________
NOTE! If all of the preceding steps have been properly
executed and the MODEL 2500 does not accept the
new program, make certain that the revision level of
the BASE25 EPROMs matches the revision level of the
Config25 program used to build the BTA file.
_________________________________________________________
________________________________________________________________________________________________________________________________________
SECTIONSECTION 33
30

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DANIEL 2500 and is the answer not in the manual?

DANIEL 2500 Specifications

General IconGeneral
BrandDANIEL
Model2500
CategoryComputer Hardware
LanguageEnglish