Enter configuration
ik
ik
DATA FORMAT
Exit & Save configuration
i k
i k
72
FIELD ADJUSTMENT CHARACTER
Read the field adjustment character code:
field adjustment character
☞
i&(k
i&(k
i&(k
Read the hexadecimal value corresponding to the character you want to use for field
adjustment.
Valid characters for all readers are in the range: 00-FE
Example:
To define the field adjustment character = A:
Read
field adjustment character
+ 41
CODE LENGTH TX
code length not transmitted
i&&:k
i&&:k
i&&:k
code length transmitted in variable-digit format
i&&=k
i&&=k
i&&=k
code length transmitted in fixed 4-digit format
i&&@k
i&&@k
i&&@k
The code length is transmitted in the message after the Headers and Code Identifier characters.
The code length is calculated after performing any field adjustment operations.