Enter configuration
ik
ik
READING PARAMETERS
Exit & Save configuration
i k
i k
81
TRIGGER-OFF TIMEOUT
trigger-off timeout
i#%k
i#%k
i#%k
Read 2 numbers in the range 00-99:
00 = disables the trigger-off timeout
01-99 = corresponds to a max. 99 sec. delay after the trigger
press to allow the reader to turn off automatically.
trigger-off timeout disabled
See par. 5.6.2 for details.
FLASH MODE
"FLASH" ON duration
i##1k
i##1k
i##1k
"FLASH" OFF duration
i##4k
i##4k
i##4k
Read 2 numbers in the range 01-99:
01 to 99 = from .1 to 9.9 seconds.
Flash-ON = 1 sec. Flash-OFF = 0.6 sec