READING FEATURES
93
6
Codabar
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
10
12
15
18
21
24
7
9
11
14
16
18
0.30
11
13
16
19
22
25
7
10
12
14
16
19
0.33
11
14
17
20
22
26
8
10
12
14
17
19
0.38
12
15
18
21
23
26
8
11
13
15
17
20
0.50
15
17
20
23
26
29
10
12
14
16
19
21
0.72
19
22
25
27
30
33
12
15
17
19
21
24
1.00
25
27
30
33
36
39
16
18
20
22
25
27
Ratio 3:1; Interdigit = Module Size
Table 4
EAN 8-13, UPC-A
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
9
12
15
18
21
23
7
9
11
13
16
18
0.30
10
13
16
19
22
24
7
9
12
14
16
18
0.33
11
14
16
19
22
25
8
10
12
14
17
19
0.38
12
15
17
20
23
26
8
10
13
15
17
19
0.50
14
17
20
22
25
28
9
12
14
16
18
21
0.72
18
21
24
27
29
32
12
14
16
19
21
23
1.00
24
26
29
32
35
38
15
17
19
22
24
26
Table 5
NOTE: To maximize scanner performance in Advanced Code
Reconstruction Reading applications:
enable only the code symbologies that will actually be used in the
application and disable any code symbologies that will not be used in the
application
reconstruct only one code label at a time