DS5100 REFERENCE MANUAL
142
C
C CONNECTIONS FOR PROFINET-IO MODELS
ON-BOARD PROFINET-IO CONNECTORS (2)
Two Standard M12 D-Coded female connectors are provided for the on-board PROFINET-IO
connection. This interface is IEEE 802.3u 100 BaseTx compliant.
Use accessory ETH CABLE M12-M12 cables or Cat 5e or superior cables.
Figure 86 - M12 D-Coded 4-pin Female PROFINET-IO Network Connector
On-Board Ethernet Network Connector Pinout
Pin
Name
Function
1
TX +
Transmitted data (+)
2
RX +
Received data (+)
3
TX -
Transmitted data (-)
4
RX -
Received data (-)
POWER + INPUT (TRIGGER)
Figure 87 - M12 A-Coded 5-pin Male Power Connector
Power Connector Pinout
Pin
Name
Function
CS-A1-02
1
Vdc
Power supply input voltage +
Brown
2
I1A
External Trigger Input (polarity insensitive)
White
3
GND
Power supply input voltage -
Blue
4
I1B
External Trigger Input (polarity insensitive)
Black
5
NC
Not Connected
nc
The CS-A1-02 or AS-I accessory power cables can be used to connect to the power source.
The CS-A1-02 cables can also be used to connect to the input trigger signal.