READING FEATURES
107
6
NOTE: (0,0) is the center of the laser beam output window.
CONDITIONS
Hardware Settings
Code Symbology
Code 128
PCS
0.90
"Pitch" angle
0
"Skew" angle
15
"Tilt" angle
0
Software Parameters
Reading Mode
Linear
For Tilt angles of 45°, the reading performance is reduced by approximately 10%.
Reading Distance
Horizontal Reading Width
8 10 12 14 16 18 20 22 24
in
0
8
-4
-6
2
6
mm
-2
-8
-10
4
10
-12
12