DS5100 REFERENCE MANUAL
70
4
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two.
The electrical features of the outputs are the following:
V
CE
= 30 Vdc max.
I
CE
= 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
= 1 Vdc max. @ 10 mA
P
D
= 90 mW Max. @ 50 °C ambient temp.
OUTPUT 1 AND 2 CONNECTIONS USING SCANNER POWER
CAUTION: Power from the Vdc/GND spring clamps is available directly to
the Output Device on the +V/-V spring clamps, and does not pass through
the Power Switch (ON/OFF) inside the CBX. Disconnect the power supply
when working inside the CBX.
Figure 49 - PNP/Open Emitter Output Using Scanner Power
Figure 50 - NPN/Open Collector Output Using Scanner Power
Power to Output
Output device Signal
Output device
Reference
Output 1 Device
Power to Output
Output device Signal
Output device
Reference
Output 2 Device
Power to
Output device
Output device
Reference
Output 1 Device
Output
Signal
Power to
Output device
Output device
Reference
Output 2 Device
Output
Signal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DS5100-X200 and is the answer not in the manual?

Datalogic DS5100-X200 Specifications

General IconGeneral
BrandDatalogic
ModelDS5100-X200
CategoryBarcode Reader
LanguageEnglish

Related product manuals