Calibration Verification (U.S. Pounds)
Product Reference Guide 5-7
Calibration Verification (U.S. Pounds)
Once you have completed the calibration sequence, you may be required
to perform these step-by-step verification procedures. These procedures
follow the National Institute of Standards and Technology Handbook-44
guidelines for grocery scale installations. You may be required by state or
local law to have these procedures performed by a certified technician or
verified by a proper official.
These calibration verification procedures cover five different tests:
Increasing-Load Test
•Shift Test
•Blanking Test
Decreasing-Load Test
Return to Zero Test
Increasing-Load Test (Phase 1)
This test checks Scale operation with five, ten and fifteen pound weights.
1. Check that the display reads 0.00 lb. when at rest with nothing on
the weighing surface. (The Yellow LED is steadily lit).
2. Place a five-pound weight on the center of the weighing surface and
check that the display reads 5.00 lb.
3. Place an additional five pounds on the center of the weighing sur-
face and check that the display reads between 9.99 and 10.01 lb.
4. Place an additional five pounds on the center of the weighing sur-
face and check that the display reads between 14.99 and 15.01.
Remove the weights and verify that the display reads 0.00.
5. You have completed the Increasing-Load Test (Phase 1).

Table of Contents

Other manuals for Datalogic MAGELLAN 8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MAGELLAN 8300 and is the answer not in the manual?

Datalogic MAGELLAN 8300 Specifications

General IconGeneral
Read rate (max)3900 reads/s
Decoding standards1D, GS1 DataBar
Standard interfacesKeyboard Wedge, RS-232
USB 2.0 ports quantity1
Input voltage100 - 250 V
Product colorMetallic
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth102 mm
Width292 mm
Height130 mm

Related product manuals