UPC/EAN Minimum Segment Length
Specifies the minimum number of characters necessary in a UPC/EAN/
JAN label segment in order for the scanner to accept a label for decoding.
Selectable from 5 to 15 characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code representing the desired option below or on the
following pages. You’ll need to cover any unused bar codes on facing
pages to ensure that the scanner reads only the bar code you intend
to scan.
Complete the programming sequence by scanning the SWITCH bar
code.
UPC/EAN MINIMUM SEGMENT LENGTH = 5 CHARACTERS
UPC/EAN MINIMUM SEGMENT LENGTH = 6 CHARACTERS

Table of Contents

Other manuals for Datalogic MAGELLAN 8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MAGELLAN 8300 and is the answer not in the manual?

Datalogic MAGELLAN 8300 Specifications

General IconGeneral
Read rate (max)3900 reads/s
Decoding standards1D, GS1 DataBar
Standard interfacesKeyboard Wedge, RS-232
USB 2.0 ports quantity1
Input voltage100 - 250 V
Product colorMetallic
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth102 mm
Width292 mm
Height130 mm