6-102 Magellan
®
8300/8400
IBM Maximum Label Slice Length
Specifies the maximum allowable length of host transmit data in each
sliced frame.
1. Scan the SWITCH bar code.
2. Scan the bar code below,
SET IBM MAXIMUM LABEL SLICE
LENGTH. You’ll need to cover any unused bar codes on this and the
facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired slice length. The selectable range is a length from
14 to 246. Pad all single and double digit numbers with leading
zeroes to yield a three-digit entry (014-100).
4. The scanner will automatically exit Programming Mode when the
appropriate amount of digits have been scanned.
SET IBM MAXIMUM LABEL SLICE LENGTH
NOTE
This setting only applies when IBM Label Slicing Control
is enabled.