EasyManua.ls Logo

Datalogic Matrix 300N - Aalternative Connections; Power, COM and I;O Connector

Datalogic Matrix 300N
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ALTERNATIVE CONNECTIONS
155
A
A ALTERNATIVE CONNECTIONS
The connector pinouts and notes given in this appendix are for custom cabling applications.
POWER, COM AND I/O CONNECTOR
The Matrix 300N reader is equipped with an M12 17-pin male connector for connection to the
power supply, serial interfaces and input/output signals. The details of the connector pins are
indicated in the following table:
Figure 78 M12 17-pin male COM, I/O and Power Connector
Power, COM and I/O Connector Pinout
Pin
Name
Function
1
Vdc
Power supply input voltage +
2
GND
Power supply input voltage -
Connector
case
CHASSIS
Connector case provides electrical connection to the
chassis
6
I1A
External Trigger A (polarity insensitive)
5
I1B
External Trigger B (polarity insensitive)
13
I2A
Input 2 A (polarity insensitive)
3
I2B
Input 2 B (polarity insensitive)
9
O1
Output 1
(NPN or PNP short circuit protected
and software programmable)
8
O2
Output 2
16
O3
Output 3
14
RX
Auxiliary RS232 RX
4
TX
Auxiliary RS232 TX
7
ID+
ID-NET network +
15
ID-
ID-NET network -
Pin
Name
RS232
RS422 Full-Duplex
17
MAIN
INTERFACE
(SW
SELECTABLE)
TX
TX+
11
RX
*RX+
12
-
TX-
10
-
*RX-
* Do not leave floating, see par. 4.2.2 for connection details.
In order to meet EMC requirements:
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
connect your cable shield to the locking ring nut of the connector.

Table of Contents