MATRIX 300N™ REFERENCE MANUAL
38
2
2.3.3 Slave Configuration
NOTE: When the Slaves are not positioned on the same plane or side as the
Master, you must configure the Slave device photometric parameters (Image
Setup) in DL.CODE through its Ethernet connection. If Slave devices do not
have an individual Ethernet connection you must temporarily (manually)
connect them one by one to perform Image Setup.
Now that the ID-NET network is configured, the Slave specific parameters need to be set.
These depend on the application and include the following:
photometric parameters (Image Setup step)
Acquisition Trigger Delays necessary to avoid lighting interference between adjacent
or oppositely positioned readers (Reading Phase step)
Images Saving if used (Data Formatting step)
Encoder Sensor: if used, (for all Slaves, the Encoder Type must be set to Internal)
To do this, click on the Getting started icon and open the Master branch to see the
connected Slaves. Each Slave can be connected to through its Ethernet interface.