2D Global Features Enter/Exit Programming Mode
Product Reference Guide
193
PDF417 Set Length 2
This feature specifies one of the bar code lengths for PDF417 Length Con-
trol. Length 2 is the maximum label length if in Variable Length Mode, or
the second fixed length if in Fixed Le
ngth Mode. Length includes the bar
code’s check, data, and full-ASCII shift characters. The length does not
include start/stop characters. Characters can be set from 01 to 2,710 char-
acters (pad with zeroes) in increments of 01
. Any value greater than 2,710
will be considered to be 2,710.
See page 290 for detailed instructions on setting this feature.
Select PDF417 Length 2 Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code t
o abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
Length 2 is 2,710 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan 9501-AR Series and is the answer not in the manual?

Datalogic PowerScan 9501-AR Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan 9501-AR Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals