References
298
PowerScan™ PD9531-AR/PBT9501-AR/PM9501-AR
Table 39
STEP ACTION EXAMPLES
1.
Scan the ENTER/EXIT bar
code
(Scanner enters Programming Mode)
2.
Determine placement of
the
Label ID characters
BEFORE or AFTER with
regard to scanned data
using
Label ID
Control, starting on
page 60
Enable as Pre-
fix
Enable as Suf-
fix
Enable as Pre-
fix
Enable as Suffix
3.
Scan the bar code
sele
cting the symbology
type you wish to
designate label ID
characters for using
Label
ID Symbology Selection
− 1D
Symbologies, starting
on page 61
.
DataBar
Omnidirec-
tional
Code 39
Interleaved 2 of
5
Code 32
4.
Custom Label ID example
(desired characters):
D B * = C 3 + P H
5.
Find hex equivalents from
the
ASCII Chart(inside
back cover), then scan in
the
se digits/characters
using the bar codes in the
section:
Keypad, starting
on page 339
. If you make
a mistake before the last
character, scan the
CANCEL bar code to abort
and not save the entry
string. You can then start
again at the beginning.
44 42 2A 3D 43 33 2B 50 48
6.
Scan the ENTER/EXIT bar
code
(Scanner exits Label ID entry)
7.
Scan the ENTER/EXIT bar
code once
again
(Scanner exits Programming Mode)
Result:
DB*[bar code
data]
[bar code
data]=C3
+[bar code
data]
[bar code data]PH
. Label ID Examples