Changing the pin code setting will unlink the devices. If the Automatic
Configuration Update is set to the default enabled setting, the devices
must only be relinked. If the Automatic Configuration Update is set to
the disabled setting, the Pin Code setting must also be updated in the
Base Station using Aladdin. After the Base Station has been updated,
the devices must be relinked.
Wireless Features
Product Reference Guide
307
Table 45. Bluetooth Pin Code Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
D254 STOR12345678135M
2
Convert the characters
to he
xadecimal
44 32 35 34 53 54 4F 52 31 32 33 34 35 36 37 38 31 33 35 4D
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SET Bluetooth PIN CODE
5
Scan 8 or 32
Alphanumeric
Characters From
Appendix D, Keypad
44323534 53544F5231323334353637383133354D
6 Scan ENTER/EXIT PROGRAMMING MODE