316 | Troubleshooting Your System
NOTE: Some software may cause the system time to speed up or slow down. If
the system seems to operate normally except for the time kept in the System
Setup program, the problem may be caused by software rather than by a
defective battery.
Troubleshooting Power Supplies
1 Identify the faulty power supply by the power supplys fault indicator.
See Power and System Board Indicator Codes on page 30.
2 Reseat the power supply by removing and reinstalling it. See Power
Supplies on page 166.
If the problem persists, replace the faulty power supply.
3 If all troubleshooting fails, see Getting Help on page 343.
Troubleshooting System Cooling Problems
Ensure that none of the following conditions exist:
System cover, cooling shroud, drive blank, power supply blank, or
front or back filler panel is removed.
CAUTION: At least one power supply must be installed for the system to operate.
Operating the system with only one power supply installed for extended periods
of time can cause the system to overheat.
NOTE: After installing a power supply, allow several seconds for the system to
recognize the power supply and to determine if it is working properly. The power
indicator turns green to signify that the power supply is functioning properly.
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.

Table of Contents

Other manuals for Dell PowerEdge C6220 II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge C6220 II and is the answer not in the manual?

Dell PowerEdge C6220 II Specifications

General IconGeneral
Form Factor2U Rack
ProcessorIntel Xeon E5-2600 v2 series
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi
MemoryUp to 512GB DDR3 per node
StorageUp to 24 x 2.5" hot-plug SAS, SATA, or SSD drives
NetworkDual 1GbE, optional 10GbE
ManagementDell Remote Access Controller (iDRAC7) with Lifecycle Controller
Number of ProcessorsUp to 2 per node (4 total in 2U chassis)
Power SupplyRedundant hot-plug power supplies