EasyManua.ls Logo

Dell PowerEdge C6220 II - ME Fail Event; SEL Generator ID

Dell PowerEdge C6220 II
349 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46 | About Your System
Byte
Field
Value
Description
8
Event Data1
AXh
01h: OEM BIOS recovery
Event
9
Event Data2
XXh
01h:Start Recovery
02h:Recovery Success
03h:Load Image Fail
04h:Signed Fail
10
Event Data3
FFh
FFh: Not Present
ME Fail Event
Byte
Field
Value
Description
1
NetFunLun
10h
2
Platform Event Command
02h
3
Generator ID
01h
Generated by BIOS
4
Event Message
Format Version
04h
Event Message Format
Revision. 04h for this
specification.
5
Sensor Type
12h
System Event
6
Sensor Number
8Ah
ME fail (depend on platform)
7
Event Direction
Event Type
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
8
Event Data1
AXh
01h: OEM ME fail Event
9
Event Data2
XXh
01h:ME fail
10
Event Data3
FFh
FFh: Not Present
SEL Generator ID
Generator ID
BIOS
0x0001
BMC
0x0020
ME
0x002C
Windows 2008
0x0137

Table of Contents

Other manuals for Dell PowerEdge C6220 II

Related product manuals