Table 17. Supported video resolution options (continued)
Resolution Refresh rate (Hz) Color depth (bits)
1680 x 1050 60 Hz 32
1920 x 1080 60 Hz 32
1920 x 1080 60 Hz (RB) 32
1920 x 1200 60 Hz 32
1920 x 1200 60 Hz (RB) 32
Environmental specifications
NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation on www.dell.com/support/home.
Table 18. Continuous Operation Specifications for ASHRAE A2
Temperature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
1035°C (5095°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above
900 m (2953 Ft).
Table 19. Continuous Operation Specifications for ASHRAE A3
Temperature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
540°C (41104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above
900 m (2953 Ft).
Table 20. Continuous Operation Specifications for ASHRAE A4
Temperature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
545°C (41113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above
900 m (2953 Ft).
Table 21. Continuous Operation Specifications for Rugged Environment
Temperature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
555°C (41131°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point