Table 26. Thermal restriction matrix(continued)
- TDP Number of Cores Configuration 1:
4x3.5-inch SATA
Configuration 2: 8x3.5-
inch SAS/SATA
HSK/FAN type HSK/FAN type
65 W 8 STD/STD STD/STD
65 W 6 STD/STD STD/STD
55 W 4 STD/STD STD/STD
46 W 2 STD/STD STD/STD
35 W 2 STD/STD STD/STD
NOTE: If BOSS or A2 GPU or a PCIe card >25 W and Broadcom 10 G NIC is installed, an HPR PCI fan and PCIe shroud are
needed for both configurations.
Thermal air restrictions
ASHRAE A3/A4 environment
● The operating temperature is for a maximum altitude of 950 m for ASHRAE A3/A4 Cooling
● Redundant power supplies are required
● BOSS module is not supported
● Cooling redundancy is not supported due to single fan in the system (cooling zone is separated)
● A2 GPU is not supported
● Non-Dell qualified peripheral cards and /or peripheral cards greater than 25 W are not supported
28
Technical specifications