Dell PowerEdge XR5610 - Installing the Processor and Extended Heat Sink Module

Dell PowerEdge XR5610
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 91. Set the anti-tilt wires to the locked position and tightening the nuts
Next steps
1. Replace the processor air shroud.
2. Follow the procedure listed in After working inside your system.
Installing the processor and extended heat sink module
Prerequisites
Never remove the heat sink from a processor unless you intend to replace the processor or system board. The heat sink is
necessary to maintain proper thermal conditions.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system .
3. Remove the processor air shroud.
4. If applicable, remove the OCP card.
5. Remove the OCP riser.
6. If applicable, remove the processor and heat sink module.
NOTE: The procedure to install the heat sink is the same for Rear Accessed and Front Accessed configurations.
Steps
1. Set the anti-tilt wires to the unlocked position on the heat sink (inward position).
2. Align the pin 1 indicator of the extended heat sink to the system board, and then place the processor and extended heat sink
on the processor socket.
CAUTION: To avoid damaging the fins on the heat sink, do not press down on the heat sink fins.
NOTE: Ensure that the processor and extended heat sink is held parallel to the system board to prevent damaging the
components.
120 Installing and removing system components