NOTE: Observe the routing of the cable as you remove it from the system.
3. Using the Torx 8 screwdriver, remove the screws that secure the status LED control panel to the system.
4. Hold the status LED control panel and remove the control panel along with the cable from the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Next steps
Replace the status LED control panel for Rear Accessed configuration.
Installing the status LED control panel for Rear Accessed
configuration
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shrouds.
4. Remove the expansion card riser 1.
NOTE: If necessary, please remove the backplane signal and power cables.
Steps
1. Align and insert the status LED control panel assembly in the slot on the system.
2. Route the status LED control panel cable through the guide slots in the system and connector on system board.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
3. Using the Torx 8 screwdriver, tighten the screws that secure the left control panel assembly to the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 132. Installing the status LED control panel for Rear Accessed configuration
4. Align and insert the left ear handle in the slot on the system and tighten the screws using Torx 8 screwdriver.